ION CONCENTRATION
3.86 million ions/cm³
Measured 5 cm from the outlet at 23.8°C and 59% relative humidity. This is an outlet-proximity measurement, not a whole-cabin concentration.
SMOGGO NOVUS · TESTING & MEASUREMENTS
Explore the laboratory measurements behind SmogGo Novus, with the test conditions that give each result context.
ION CONCENTRATION
Measured 5 cm from the outlet at 23.8°C and 59% relative humidity. This is an outlet-proximity measurement, not a whole-cabin concentration.
OZONE MEASUREMENT
Measured 5 cm from the outlet during rated operation. The report lists a limit of ≤0.10 mg/m³. This is a measured concentration, not a zero-ozone claim.
BACTERIAL TEST · 2 HOURS
Reduction of Staphylococcus albus 8032 in a 1 m³ test chamber after 2 hours, with natural decay accounted for. This result concerns the tested organism under the stated laboratory conditions.
FORMALDEHYDE · 24 HOURS
Concentration reduced from 2.18 to 0.52 mg/m³ over 24 hours in a sealed 60-litre glass chamber.
BENZENE · 24 HOURS
Concentration reduced from 2.02 to 0.46 mg/m³ over 24 hours in a sealed 60-litre glass chamber.
E. COLI TEST · 24 HOURS
Reported for E. coli 8099 in a laboratory test recording counts per test carrier after 24 hours. This is not a whole-cabin airborne removal measurement.
CONFORMITY DOCUMENTATION
Product documentation covers electromagnetic compatibility, restricted substances and radio-frequency emissions. Each document addresses a specific requirement.
CE · EMC
Documentation references the EMC Directive 2014/30/EU and standards EN 55014-1:2017 and EN 55014-2:2015.
RoHS
Documentation references Directive (EU) 2015/863 amending 2011/65/EU, with testing to the IEC 62321 series.
FCC
Documentation references FCC Part 15, Subpart B, for the tested product configuration.
Conformity documentation applies within its stated scope. It is separate from the purification measurements above and does not establish medical effectiveness or government endorsement.
Different tests use different chamber sizes, organisms, exposure times and sampling methods. Their percentages should not be combined or treated as directly comparable. Ion concentration alone does not establish removal performance.
These measurements relate to the original SmogGo Novus. They are not test results for the upcoming Novus USB or Novus PRO.
Results are based on laboratory testing under specified conditions. Actual performance varies with cabin size, ventilation, pollutant levels, operating time and usage. Laboratory outcomes do not guarantee identical performance in every vehicle. The results do not establish medical benefits, virus removal or prevention of illness. SmogGo Novus is not a medical device.
Measurement summaries are provided for customer information.